Added remaining tests for viscosity - only a few do not pass

Signed-off-by: Ian Bell <ian.h.bell@gmail.com>
This commit is contained in:
Ian Bell
2014-05-22 23:52:04 +02:00
parent bc5c75d06b
commit 6ec5574b76
2 changed files with 17 additions and 11 deletions

View File

@@ -188,6 +188,15 @@ vel("R23", "T", 370, "Dmolar", 32.62, "V", 18.213e-6, 1e-4),
vel("Ethane", "T", 100, "Dmolar", 21330, "V", 878.6e-6, 1e-2),
vel("Ethane", "T", 430, "Dmolar", 12780, "V", 58.70e-6, 1e-2),
vel("Ethane", "T", 500, "Dmolar", 11210, "V", 48.34e-6, 1e-2),
// From REFPROP 9.1 since no data provided
vel("n-Butane", "T", 150, "Q", 0, "V", 0.0013697657668, 1e-4),
vel("n-Butane", "T", 400, "Q", 1, "V", 1.2027464524762453e-005, 1e-4),
vel("IsoButane", "T", 120, "Q", 0, "V", 0.0060558450757844271, 1e-4),
vel("IsoButane", "T", 400, "Q", 1, "V", 1.4761041187617117e-005, 2e-4),
vel("R134a", "T", 175, "Q", 0, "V", 0.0017558494524138289, 1e-4),
vel("R134a", "T", 360, "Q", 1, "V", 1.7140264998576107e-005, 1e-4),
};
class ViscosityValidationFixture