mirror of
https://github.com/CoolProp/CoolProp.git
synced 2026-04-23 03:00:17 -04:00
Slight improvement in water critical conductivity term - all within 0.02% error now
Signed-off-by: Ian Bell <ian.h.bell@gmail.com>
This commit is contained in:
@@ -226,12 +226,12 @@ long double TransportRoutines::viscosity_water_hardcoded(HelmholtzEOSMixtureBack
|
||||
double delta,tau,mubar_0,mubar_1,mubar_2,drhodp,drhodp_R,DeltaChibar,zeta,w,L,Y,psi_D,Tbar,rhobar;
|
||||
double drhobar_dpbar,drhobar_dpbar_R,R_Water;
|
||||
|
||||
pstar = 22.064e6;
|
||||
Tstar = 647.096;
|
||||
rhostar = 322;
|
||||
pstar = 22.064e6; // [Pa]
|
||||
Tstar = 647.096; // [K]
|
||||
rhostar = 322; // [kg/m^3]
|
||||
Tbar = HEOS.T()/Tstar;
|
||||
rhobar = HEOS.keyed_output(CoolProp::iDmass)/rhostar;
|
||||
R_Water = HEOS.gas_constant()/HEOS.molar_mass();
|
||||
rhobar = HEOS.rhomass()/rhostar;
|
||||
R_Water = HEOS.gas_constant()/HEOS.molar_mass(); // [J/kg/K]
|
||||
|
||||
// Dilute and finite gas portions
|
||||
visc_Helper(Tbar, rhobar, &mubar_0, &mubar_1);
|
||||
@@ -678,9 +678,10 @@ long double TransportRoutines::conductivity_hardcoded_water(HelmholtzEOSMixtureB
|
||||
double drhobar_dpbar = pstar/rhostar*drhodp;
|
||||
double drhodp_Trbar = 1/(R*Tr_bar*Tstar*(1+2*rhobar*HEOS.calc_alphar_deriv_nocache(0,1,HEOS.mole_fractions,1/Tr_bar,delta)+delta*delta*HEOS.calc_alphar_deriv_nocache(0,2,HEOS.mole_fractions,1/Tr_bar,delta)));
|
||||
double drhobar_dpbar_Trbar = pstar/rhostar*drhodp_Trbar;
|
||||
double cp = HEOS.cpmolar(); // [J/mol/K]
|
||||
double cv = HEOS.cvmolar(); // [J/mol/K]
|
||||
double cpbar = cp/8.31447215; //[-]
|
||||
double cpmol = HEOS.cpmolar(); // [J/mol/K]
|
||||
double cp = HEOS.cpmass(); // [J/kg/K]
|
||||
double cv = HEOS.cvmass(); // [J/kg/K]
|
||||
double cpbar = cp/R; //[-]
|
||||
double mubar = HEOS.viscosity()/mustar;
|
||||
double DELTAchibar_T = rhobar*(drhobar_dpbar-drhobar_dpbar_Trbar*Tr_bar/Tbar);
|
||||
if (DELTAchibar_T<0)
|
||||
|
||||
Reference in New Issue