QT inputs should only be valid for pseudo-pure if Q=0 or Q=1; closes #636
This commit is contained in:
@@ -275,12 +275,7 @@ void FlashRoutines::QT_flash(HelmholtzEOSMixtureBackend &HEOS)
|
||||
HEOS._rhomolar = HEOS.SatV->rhomolar();
|
||||
}
|
||||
else{
|
||||
CoolPropDbl psatLanc = HEOS.components[0].ancillaries.pL.evaluate(HEOS._T); // These ancillaries are used explicitly
|
||||
CoolPropDbl psatVanc = HEOS.components[0].ancillaries.pV.evaluate(HEOS._T); // These ancillaries are used explicitly
|
||||
HEOS._p = HEOS._Q*psatVanc + (1-HEOS._Q)*psatLanc;
|
||||
HEOS._rhomolar = 1/(HEOS._Q/HEOS.SatV->rhomolar() + (1 - HEOS._Q)/HEOS.SatL->rhomolar());
|
||||
HEOS.SatL->update(DmolarT_INPUTS, rhoLsat, HEOS._T);
|
||||
HEOS.SatV->update(DmolarT_INPUTS, rhoVsat, HEOS._T);
|
||||
throw CoolProp::ValueError(format("For pseudo-pure fluid, quality must be equal to 0 or 1. Two-phase quality is not defined"));
|
||||
}
|
||||
|
||||
try{
|
||||
|
||||