Shelley Vohr 7c0cb61b3c fix: prevent use-after-free in PowerMonitor via dangling OS callbacks (#50045)
PowerMonitor registered OS-level callbacks (HWND UserData and
WTS/suspend notifications on Windows, shutdown handler and lock-screen
observer on macOS) but never cleaned them up in its destructor. The JS
layer also only held the native object in a closure-local variable,
allowing GC to reclaim it while those registrations still referenced
freed memory.

Retain the native PowerMonitor at module level in power-monitor.ts so
it cannot be garbage-collected. Add DestroyPlatformSpecificMonitors()
to properly tear down OS registrations on destruction: on Windows,
unregister WTS and suspend notifications, clear GWLP_USERDATA, and
destroy the HWND; on macOS, remove the emitter from the global
MacLockMonitor and reset the Browser shutdown handler.
2026-03-05 09:00:37 -06:00
..