SecCool data does not come with unified units, we need another parameter

This commit is contained in:
Jorrit Wronski
2015-12-20 18:33:40 +01:00
parent 3510566701
commit 7b6f5f683a

View File

@@ -13,7 +13,7 @@ class SecCoolSolutionData(DigitalData):
to read data files sitting in data/SecCool/xMass and
data/SecCool/xVolume.
"""
def __init__(self,sFile=None,sFolder=None,name=None,desc=None,ref='SecCool software'):
def __init__(self,sFile=None,sFolder=None,name=None,desc=None,ref='SecCool software',densityFactor=None,heatFactor=None,conductivityFactor=None,viscosityFactor=None):
DigitalData.__init__(self)
self.allowNegativeData = False
@@ -48,11 +48,11 @@ class SecCoolSolutionData(DigitalData):
raise ValueError("Unknown folder type specified.")
self.TminPsat = self.Tmax
try:
self.density.xData,self.density.yData,self.density.data = self.getArray(dataID="Rho")
while np.max(self.density.data[np.isfinite(self.density.data)])<500: # Expect values around 1e3
self.density.data *= 10.0
#while np.max(self.density.data[np.isfinite(self.density.data)])<500: # Expect values around 1e3
# self.density.data *= 10.0
if densityFactor is not None: self.density.data *= densityFactor
self.density.source = self.density.SOURCE_DATA
except:
if self.density.DEBUG: print("Could not load {}".format(self.getFile("Rho")))
@@ -60,8 +60,9 @@ class SecCoolSolutionData(DigitalData):
try:
self.specific_heat.xData,self.specific_heat.yData,self.specific_heat.data = self.getArray(dataID='Cp')
while np.max(self.specific_heat.data[np.isfinite(self.specific_heat.data)])<1000: # Expect values around 2e3
self.specific_heat.data *= 10.0
#while np.max(self.specific_heat.data[np.isfinite(self.specific_heat.data)])<1000: # Expect values around 2e3
# self.specific_heat.data *= 10.0
if heatFactor is not None: self.specific_heat.data *= heatFactor
self.specific_heat.source = self.specific_heat.SOURCE_DATA
except:
if self.specific_heat.DEBUG: print("Could not load {}".format(self.getFile("Cp")))
@@ -69,8 +70,9 @@ class SecCoolSolutionData(DigitalData):
try:
self.conductivity.xData,self.conductivity.yData,self.conductivity.data = self.getArray(dataID='Cond')
while np.max(self.conductivity.data[np.isfinite(self.conductivity.data)])>2: # Expect value below 1
self.conductivity.data *= 0.1
#while np.max(self.conductivity.data[np.isfinite(self.conductivity.data)])>2: # Expect value below 1
# self.conductivity.data *= 0.1
if conductivityFactor is not None: self.conductivity.data *= conductivityFactor
self.conductivity.source = self.conductivity.SOURCE_DATA
except:
if self.conductivity.DEBUG: print("Could not load {}".format(self.getFile("Cond")))
@@ -78,8 +80,9 @@ class SecCoolSolutionData(DigitalData):
try:
self.viscosity.xData,self.viscosity.yData,self.viscosity.data = self.getArray(dataID='Mu')
while np.max(self.viscosity.data[np.isfinite(self.viscosity.data)])>0.2: # Expect value below 0.1
self.viscosity.data *= 0.1
#while np.max(self.viscosity.data[np.isfinite(self.viscosity.data)])>0.2: # Expect value below 0.1
# self.viscosity.data *= 0.1
if viscosityFactor is not None: self.viscosity.data *= viscosityFactor
self.viscosity.source = self.viscosity.SOURCE_DATA
except: