mirror of
https://github.com/CoolProp/CoolProp.git
synced 2026-04-23 03:00:17 -04:00
Implement prediction of critical density based on Tc/pc ratio as suggested by A. Kazakov
This commit is contained in:
@@ -17,10 +17,11 @@ void CoolProp::AbstractCubicBackend::get_linear_reducing_parameters(double &rhom
|
||||
T_r = 0;
|
||||
double v_r = 0;
|
||||
const std::vector<double> Tc = cubic->get_Tc(), pc = cubic->get_pc();
|
||||
std::vector<double> rhoc(2,10139.128); rhoc[1] = 6856.886685;
|
||||
for (std::size_t i = 0; i < mole_fractions.size(); ++i){
|
||||
T_r += mole_fractions[i]*Tc[i];
|
||||
v_r += mole_fractions[i]/rhoc[i];
|
||||
// Curve fit from all the pure fluids in CoolProp (thanks to recommendation of A. Kazakov)
|
||||
double v_c_Lmol = 2.14107171795*(Tc[i]/pc[i]*1000)+0.00773144012514; // [L/mol]
|
||||
v_r += mole_fractions[i]*v_c_Lmol/1000.0;
|
||||
}
|
||||
rhomolar_r = 1/v_r;
|
||||
}
|
||||
|
||||
Reference in New Issue