158 Commits

Author SHA1 Message Date
jdeath
12e9167168 Merge pull request #48 from jogoodma/main
Add support for 'FR:J' serial numbers
4.8
2025-05-28 06:12:33 -04:00
Josh Goodman
32ffd0c5c5 Add support for 'FR:J' serial numbers 2025-05-27 23:44:04 -04:00
jdeath
6ce73c72b4 Update README.md 2024-04-22 06:51:49 -04:00
jdeath
2e33c1b995 Update config_flow.py 4.7 2024-04-21 16:28:15 -04:00
jdeath
ab1c6ea496 Update manifest.json 2024-04-21 16:27:06 -04:00
jdeath
6f4e83fecb Update README.md 2024-03-22 23:33:38 -04:00
jdeath
a7c4ce2a31 Update config_flow.py 4.6 2024-03-22 23:29:24 -04:00
jdeath
243e735798 Update manifest.json 2024-03-22 23:28:46 -04:00
jdeath
8153ddc9b1 Merge pull request #42 from kyle2222/main 2024-03-17 15:28:44 -04:00
Kyle Austin
dbb644d4b6 added new FR:IA prefix for Feb 2024 vintage device 2024-03-13 17:03:47 -07:00
Kyle Austin
686c0ada9d add prefix FR:IA for RD200 device manufactured in Feb 2024 2024-03-13 17:00:41 -07:00
jdeath
d317359fd9 Suport HG 4.5 2024-03-05 17:38:54 -05:00
jdeath
10f0bd19a2 Support HG 2024-03-05 17:38:07 -05:00
jdeath
054679b847 Merge pull request #40 from bojanrajkovic/patch-1
chore: update for new sn prefix
4.4
2024-02-25 20:02:08 -05:00
Bojan Rajkovic
1589cf9413 chore: slightly better manifest cleanup 2024-02-25 19:16:18 -05:00
Bojan Rajkovic
4ec1397812 chore: fix accidental mangling in readme 2024-02-25 19:14:44 -05:00
Bojan Rajkovic
6b53e9ec52 chore: update readme with fr:hl serial prefix 2024-02-25 19:13:55 -05:00
Bojan Rajkovic
483792c4cc chore: update manifest to include new serial number
also reformat indentation to be easier-to-read/modify a bit
2024-02-25 19:13:12 -05:00
Bojan Rajkovic
292763c4e2 chore: update config_flow with new sn prefix
Looks like they've started using FR:HL, as the unit I just got has that prefix. Add it to the discovery list.
2024-02-25 19:11:30 -05:00
jdeath
ef182353e1 Update README.md 2024-01-16 17:57:36 -05:00
jdeath
26add70f86 Update README.md 2024-01-16 17:56:19 -05:00
jdeath
9cef125534 Update README.md 4.3 2024-01-15 16:08:16 -05:00
jdeath
614b55bc85 Update manifest.json 2024-01-15 16:07:49 -05:00
jdeath
c50970ad20 Update config_flow.py 2024-01-15 16:07:06 -05:00
jdeath
e143d34d9a Update README.md 2024-01-06 08:04:03 -05:00
jdeath
0c0a7c58ba Update README.md 2024-01-06 08:02:15 -05:00
jdeath
6479f8a1d8 add FR:HJ 2024-01-06 07:59:39 -05:00
jdeath
66a8bffdf3 Update config_flow.py 4.2 2024-01-06 07:44:29 -05:00
jdeath
76493264dc Update manifest.json 2024-01-06 07:43:27 -05:00
jdeath
2165271c13 Add strict typing and close stale connections
Copy strict typing (thanks @cdce8p) and close stale connections (Thanks @LaStrada) from airthings component.
2024-01-05 17:31:52 -05:00
jdeath
0d81add0bd Avoid mutating entity descriptions
Copied from airthings_ble by @emontnemery . 

Not sure why needed, but required for 2024.1
4.1
2024-01-03 17:15:31 -05:00
jdeath
cf6d723a0f Create hassfest.yaml 4.0 2023-12-24 07:39:24 -05:00
jdeath
ef0b176b05 Create validate.yaml 2023-12-24 07:37:58 -05:00
jdeath
5ecd7aaadb Delete .github/workflows/build-test.yaml 2023-12-24 07:32:14 -05:00
jdeath
1a39d84dc9 Update README.md 2023-12-10 18:40:39 -05:00
jdeath
0ed5f9b002 Update config_flow.py 3.9 2023-12-10 18:38:54 -05:00
jdeath
8a693ed486 Update manifest.json 2023-12-10 18:38:23 -05:00
jdeath
0859ddcf89 Update config_flow.py 3.8 2023-11-28 17:45:19 -05:00
jdeath
79fdf6b8be Update manifest.json 2023-11-28 17:44:39 -05:00
jdeath
59e802dc6c Update README.md 3.7 2023-11-08 06:26:43 -05:00
jdeath
258d73c2c0 Update README.md 2023-11-08 06:23:53 -05:00
jdeath
8302381dce Update README.md 2023-11-08 06:23:07 -05:00
jdeath
4b21ed579a Merge pull request #28 from farlight1/main
- Added ion chamber "C" pulse count sensor:
2023-11-08 06:20:18 -05:00
farlight
304de78c68 - Added ion chamber "C" pulse count:
Now - Actual count pulses (note that this is a real time parameter and it is updated on the device when the ion chamber fires, as we read the device every 10 minutes in HA it may not make sense.
          Users who want to use this parameter should consider changing DEFAULT_SCAN_INTERVAL in const.py to 1min (60) or almost 2min (120).
    Last - Last 10min pulse count until next radon value update.

this is a great way to know if radon is increasing or decreasing if Now value is more than Last, open your windows :)

- Changed manufacturer to FTLAB Co., LTD.", since Ecosense is only a reseller, more info on homepage: https://radonftlab.com

- Added the new pulse values to README.md
2023-11-08 11:04:13 +01:00
jdeath
aca00a275b Update config_flow.py 3.6 2023-10-20 18:06:27 -04:00
jdeath
189bce335b Update manifest.json 2023-10-20 18:05:58 -04:00
jdeath
34aa72707b Update README.md 2023-10-20 18:05:34 -04:00
jdeath
c4215a5688 Add FR:FB Series 3.5 2023-10-20 06:28:53 -04:00
jdeath
db8dc39783 Add FR:FB 2023-10-20 06:27:18 -04:00
jdeath
231bf3d9b2 Merge pull request #24 from BigThunderSR/jdeath/rd200v2
Added "FR:HD" to the list of supported serial numbers
2023-10-17 22:11:28 -04:00